Motion test with EGIL200
Learn how to set up the EGIL200 for testing a motion measurement. This application note includes transducer example for relative measurement with common mechanism, with both analogue and digital types.
Опубликованный 15 июня 2023
Скачать PDF
Directional earth-fault protection - SVERKER 900
The fault current is set to 80mA tosimulatethe high current generated at the intermittent earth fault. The zero voltage is set to 20V;theconfiguration ismade in13 states.The fault states and the first two memory states are set to 20ms. The memory states havetimesselected togetthetrip as close to set time 1,2s as possible. In generator configuration,set U4gen to aux voltage DC.Set “Advanced mode” in SVERKER configuration.
Опубликованный 28 апреля 2022
Скачать PDF
Case study: NB DFR on HV CVTs
Reducing the risk of failure on high voltage instrument transformers in the transmission system using the application of narrowband dielectric frequency response (NB DFR) on HV CVTs.
Опубликованный 10 марта 2021
Скачать PDF
Measuring cable impedance with SVERKER900
This is an easy solution to measure the impedance values for cables, the values are used for calculation of compensation factor in distance protection.The compensation factor is first theoretically calculated and these values can now be compared with the measured values.
Опубликованный 14 декабря 2020
Скачать PDF
Preventive maintenance of rolling stock
The test and maintenance of electrical components on rolling stock is not an easy job to do. Some maintainers dismount some of the parts and bring them to a central location for revision and maintenance. This is a cumbersome and time consuming exercise. In many cases, the electrical parts are replaced only when they break down and are not subject to periodical testing. This of course holds a risk as some parts, e.g. circuit breakers, are crucial for safety reasons.
Опубликованный 3 ноября 2020
Скачать PDF
Case Study on IDAX300 and VAX020
The Power Grid Corporation of India Limited (PGCIL) is an Indian state-owned company headquartered in Gurugram (North India) engaged mainly in Trans-mission of Power and transmits about 50% of the total power generated in India on its transmission network. The company owns and operates about 1,61,790 circuit kms of transmission lines at 800/765 kV, 400 kV, 220 kV & 132 kV EHVAC and +500 kV HVDC levels and 248 sub-stations. Also, it has the transformation capacity of about 396 825 MVA as of 30th November 2019.
Опубликованный 26 августа 2020
Скачать PDF
TTRU3 Factory ratio testing of power transformer
Transformer equipment manufacturers (OEMs) have a critical need to measure true ratio, as they must confirm proper manufacture of their transformers during construction and final assembly. Improper construction has consequences of higher cost, late delivery, and poor quality. The ability of a ratio instrument to be used for all steps involved makes it a practical valueto OEMs because only one instrument is purchased and used throughout each stage. Only the most reliable and accurate instruments make it to the factory floor. Winding stack under constructionre used: Art Mandigo Winding Service.
Опубликованный 3 августа 2020
Скачать PDF